Biosafety Cabinet B2


Introduction


Biosafety protection is essential in laboratories handling biological agents, infectious samples, and hazardous materials. A reliable containment system helps protect laboratory personnel, experimental samples, and the surrounding environment from potential contamination risks.


Cigeair Biosafety Cabinet B2 is a Class II Type B2 biological safety cabinet designed according to the Chinese CFDA YY0569 standard. With a vertical laminar airflow system, negative pressure containment design, and 100% exhaust airflow structure, it provides a high level of protection for laboratories requiring strict biological safety control.


The cabinet is widely used in pharmaceutical research, biotechnology laboratories, medical testing centers, disease control facilities, and other professional environments where reliable containment performance is required.


What Is a Biosafety Cabinet B2?


A Biosafety Cabinet B2 is a Class II biological safety cabinet that provides triple protection for operators, products, and the laboratory environment.


Unlike Type A2 biosafety cabinets, which recirculate part of the filtered air inside the cabinet, the B2 model adopts a full exhaust design. All airflow is discharged through the exhaust system after HEPA filtration, preventing contaminated air from being returned to the working environment.


This design makes the Biosafety Cabinet B2 suitable for applications involving higher biological risks or processes requiring complete exhaust protection.


Working Principle


The Biosafety Cabinet B2 operates through a vertical laminar airflow negative pressure system.


During operation, room air enters through the front opening and creates an inward airflow barrier to prevent contaminated air from escaping. The air then passes through high-efficiency filtration before entering the working area as clean vertical airflow.


After passing through the working zone, all air is collected and discharged through the exhaust system after filtration.


The 100% exhaust airflow structure provides enhanced containment performance and ensures stable protection during biological operations.


Main Features


100% Exhaust Airflow Design


The cabinet uses a complete exhaust airflow structure, where all air is discharged after filtration.


Main benefits include:


Higher containment performance


Reduced risk of air recirculation


Suitable for connection with external exhaust systems


Improved laboratory safety


Vertical Laminar Flow Technology


The vertical airflow design creates a stable and uniform clean working area.


It helps reduce airborne contamination while maintaining reliable protection for samples and operators.


Advantages include:


Uniform airflow distribution


Stable working environment


Reduced turbulence


Effective contamination control


Intelligent LCD Control System


The Biosafety Cabinet B2 is equipped with a high-definition LCD color human-machine interface with touch operation.


The display provides real-time information including:


Air velocity


Filter operating status


System conditions


Fault alarms


The intelligent monitoring system helps operators quickly identify equipment status and improve daily operation efficiency.


Energy-Efficient DC Brushless Fan


The cabinet uses a DC brushless constant airflow fan with excellent energy-saving performance.


The fan supports stepless speed adjustment, maintaining stable airflow while reducing energy consumption and extending filter service life.


Key advantages include:


Low energy consumption


Low operating noise


Stable airflow control


Long service life


Typical Applications


Pharmaceutical Laboratories


Used for biological sample handling, microbiological testing, and pharmaceutical research where strict contamination control is required.


Biotechnology Facilities


Provides a safe working environment for cell culture, biological experiments, and research activities involving biological materials.


Medical and Clinical Laboratories


Supports laboratory testing and sample processing while improving operator protection.


Disease Control Centers


Suitable for laboratories requiring reliable containment when handling biological samples.


Research Institutions


Provides controlled airflow protection for universities and scientific research laboratories.


Product Advantages


Cigeair Biosafety Cabinet B2 provides reliable protection through advanced airflow technology and intelligent control systems.


Main advantages include:


Compliance with YY0569 B2-type biosafety cabinet requirements


100% exhaust airflow protection


High-efficiency HEPA filtration


Real-time monitoring and alarm system


Energy-efficient fan technology


Stable negative pressure operation


Factory safety and performance testing before delivery


The optimized design ensures long-term reliability and safe operation in demanding laboratory environments.


Why Choose Cigeair?


Cigeair provides professional biosafety and cleanroom equipment solutions for pharmaceutical, healthcare, biotechnology, and research industries.


Our Biosafety Cabinet B2 combines advanced engineering design, reliable filtration technology, and user-friendly operation to meet modern laboratory safety requirements.


We provide customized solutions based on laboratory layout, exhaust requirements, and application conditions to help customers achieve safer and more efficient laboratory environments.


Contact Us


Looking for a reliable Class II Type B2 Biosafety Cabinet for your laboratory?


Cigeair provides high-performance biosafety cabinet solutions designed for pharmaceutical laboratories, biotechnology facilities, hospitals, and research institutions.


Contact our technical team today to learn more about Biosafety Cabinet B2 specifications and customized laboratory safety solutions.



Biosafety Cabinet B2-1




 Tel: +86-755-89526537
           +86-755-89526536
 Email: zksjjh@zksjjh.com
 Add: Room 1819, Building 5A, Fenglong Shengang, No. 333 Longfei Avenue, Longcheng Street, Longgang District, Shenzhen, Guangdong, China

Quick Links

Product Category

Copyright © 2025 TKSAGE (Shenzhen) Technology Group Co., Ltd. All Rights Reserved I Sitemap I Privacy Policy