Biosafety Cabinet A2
Compliant with the requirements of Chinese CFDA YY0569 standard for A2-type secondary biosafety cabinet.
Adopts a vertical laminar flow negative pressure model, where 70% of the airflow is recycled after filtration, while 30% of the airflow can be discharged indoors or connected to the exhaust system.
Features a high-definition LCD color human-machine interface with touch key operation, providing real-time display of wind speed, filter operating status, and fault alarms.
Utilizes a unique DC brushless constant airflow fan, known for its efficiency and energy-saving properties. This fan allows for stepless speed regulation and effec - tively extends the filter's lifespan.
Each biosafety cabinet is factory-tested for safety and product performance in accordance with international standards.
Main technical parameters:
| Model | TKSAGE-BSC-1200IIA2 | TKSAGE-BSC-1500IIA2 | TKSAGE-BSC-1800IIA2 | TKSAGE-BSC-2000IIA2 | ||
| Filtering efficiency | ≥99.9995%,@0.12μm | |||||
| Supply and exhaust air filters | ULPA Air Filter | |||||
| Cleanliness level | ISO 4 | |||||
| Product execution standards | YY0569-2011( GB 4793.1-2007、GB/T 18268.1-2010) | |||||
| Descending air speed (m/s) | 0.35 m/s | |||||
| Inflow air speed (m/s) | 0.55 m/s | |||||
| Noise | 58~65 dB(A) | |||||
| Vibration | Center position of countertop ≤ 5μM | |||||
| Power supply | AC220V,1Φ,50Hz | |||||
| Opening height of sliding door | 200mm | |||||
| Airflow averaging bioprotection | Personnel protection | a. Total colony count in the impact chamber sampler ≤10CFU/times b. Total colony count in slit sampler ≤5CFU/times | ||||
| Test product protection | Total colony count ≤5CFU/times | |||||
| Cross infection protection | Total colony count ≤2CFU/times | |||||
| Max rated power (including s pare socket) | 2.0 KVA | 2.0 KVA | 2.0 KVA | 2.0 KVA | ||
| Rated power (excluding spare sockets) | 0.85 KVA | 0.85 KVA | 0.85 KVA | 0.85 KVA | ||
| Weight | 260 kg | 300 kg | 360 kg | 400 kg | ||
| Work area dimensions (mm) | 1000*630*630mm | 1300*630*630mm | 1600*630*630mm | 1800*630*630mm | ||
| Overall dimensions (mm) | 1200*795*2050mm | 1500*795*2050mm | 1800*795*2050mm | 2000*795*2050mm | ||
| Fluorescent lamp specifications (W) and quantity | 36 W*① | 48 W*① | 60 W*① | 68 W*① | ||
| UV lamp specifications (W) and quantity | 30 W*① | 30 W*① | 40 W*① | 40 W*① | ||
| llumination | ≥900 Lx | |||||
| Box Structure | Outer box structure | High quality cold-rolled steel plate electrostatic powder coating (ivory white) | ||||
| Workplace structure | High quality 304 stainless steel three sided integrated molding | |||||
| Exhaust direction | Top out | |||||
Biosafety Cabinet B2
Compliant with the requirements of the Chinese CFDA YY0569 standard for B2-type secondary biosafety cabinets.
Adopts a vertical laminar flow negative pressure model, where 100% of the airflow is discharged indoors or connected to the exhaust system after filtration.
Features a high-definition LCD color human-machine interface with touch key operation, providing real-time display of wind speed, filter operating status, and fault alarms.
Utilizes a unique DC brushless constant airflow fan, known for its efficiency and energy-saving properties. This fan allows for stepless speed regulation and effec - tively extends the filter's lifespan.
Each biosafety cabinet is factory-tested for safety and product performance in accordance with international standards.
Main technical parameters:
| Model | TKSAGE-BSC-1200IIB2 | TKSAGE-BSC-1500IIB2 | TKSAGE-BSC-1800IIB2 | TKSAGE-BSC-2000IIB2 | ||
| Filtering efficiency | ≥99.9995%,@0.12μm | |||||
| Supply and exhaust air filters | ULPA Air Filter | |||||
| Cleanliness level | ISO 4 | |||||
| Product execution standards | YY0569-2011( GB 4793.1-2007、GB/T 18268.1-2010) | |||||
| Descending air speed (m/s) | 0.35 m/s | |||||
| Inflow air speed (m/s) | 0.55 m/s | |||||
| Noise | 58~65 dB(A) | |||||
| Vibration | Center position of countertop ≤5μm | |||||
| Power supply | AC220V,1Φ,50Hz | |||||
| Opening height of sliding door | 200mm | |||||
| Airflow averaging bioprotection | Personnel protection | a. Total colony count in the impact chamber sampler ≤10CFU/times b. Total colony count in slit sampler ≤5CFU/times | ||||
| Test product protection | Total colony count ≤5CFU/times | |||||
| Cross infection protection | Total colony count ≤2CFU/times | |||||
| Max rated power (including s pare socket) | 2.0 KVA | 2.0 KVA | 2.0 KVA | 2.0 KVA | ||
| Rated power (excluding spare sockets) | 0.85 KVA | 0.85 KVA | 0.85 KVA | 0.85 KVA | ||
| Weight | 260 kg | 300 kg | 360 kg | 400 kg | ||
| Work area dimensions (mm) | 1000*630*630mm | 1300*630*630mm | 1600*630*630mm | 1800*630*630mm | ||
| Overall dimensions (mm) | 1200*795*2050mm | 1500*795*2050mm | 1800*795*2050mm | 2000*795*2050mm | ||
| Fluorescent lamp specifications (W) and quantity | 36 W*① | 48 W*① | 60 W*① | 68 W*① | ||
| UV lamp specifications (W) and quantity | 30 W*① | 30 W*① | 40 W*① | 40 W*① | ||
| llumination | ≥900 Lx | |||||
| Box Structure | Outer box structure | High quality cold-rolled steel plate electrostatic powder coating (ivory white) | ||||
| Workplace structure | High quality 304 stainless steel three sided integrated molding | |||||
| Exhaust direction | Top out | |||||